Series A3000 Photohelic Pressure Switch Gage Series A3000 Photohelic Pressure Switch Gage Series A3000 Photohelic Pressure Switch Gage Series A3000 Photohelic Pressure Switch Gage Series A3000 Photohelic Pressure Switch Gage Series A3000 Photohelic Pressure Switch Gage
Series A3000 Photohelic Pressure Switch Gage
Series A3000 Photohelic Pressure Switch Gage Series A3000 Photohelic Pressure Switch Gage Series A3000 Photohelic Pressure Switch Gage Series A3000 Photohelic Pressure Switch Gage Series A3000 Photohelic Pressure Switch Gage

Series A3000 Photohelic Pressure Switch Gage

40000 INR/Piece

Product Details:

X

Series A3000 Photohelic Pressure Switch Gage Price And Quantity

  • 1 Piece
  • 40000 INR/Piece

Series A3000 Photohelic Pressure Switch Gage Trade Information

  • Western Europe Australia Middle East Central America South America Asia North America Africa
  • Dadra and Nagar Haveli Chandigarh Himachal Pradesh Andaman and Nicobar Islands Uttarakhand Daman and Diu Lakshadweep South India North India East India Andhra Pradesh Assam Arunachal Pradesh Bihar Delhi Gujarat Goa Haryana Jammu and Kashmir Jharkhand Karnataka Kerala Madhya Pradesh Maharashtra Mizoram Meghalaya Manipur Odisha Punjab Pondicherry Rajasthan Sikkim Telangana Tripura Uttar Pradesh West Bengal Nagaland Tamil Nadu Central India West India Chhattisgarh All India

Product Description

Series A3000 Photohelic Pressure Switch/Gage

3-in-1 Indicating Gage, Lo-limit and Hi-limit Control


The Series A3000 Photohelic Switch/Gages function as versatile, highly repeatable pressure switches combined with a precise pressure gage employing the time-proven Magneheli gage design. The Photohelic switch/gage measures and controls positive, negative or differential pressures of air and compatible gases. Standard models are rated to 25 psig (1.7 bar) with options to 35 (2.4) or 80 (5.5 bar) psig. Two phototransistor actuated, DPDT relays are included for low/high limit control. Easy to adjust set point indicators are controlled by knobs located on the gage face. Individual set point deadband is one pointer width - less than 1% of full scale. Set points can be interlocked to provide variable deadband - ideal for control of fans, dampers, etc. Gage reading is continuous and unaffected by switch operation, even during loss of electrical power. Choose from full scale pressure ranges from a low 0-.25 in (0-6 mm) w.c. up to 30 psi (21 bar).


Product Applications

Air Conditioning Systems

Clean Rooms

Fume Exhaust Systems


Model

Description

A3000-0

Pressure switch/gage, range 0-.50" w.c.

A3000-00

Pressure switch/gage, range 0-.25" w.c.

A3000-00AV

Pressure switch/gage, range 0-.25" w.c./300-2000 FPM. Note: Pitot tube required.

A3000-00N

Pressure switch/gage, range .05 to .20" w.c.

A3000-0AV

Pressure switch/gage, range 0-.50" w.c./500-2800 FPM. Note: Pitot tube required.

A3000-1.5KPA

Pressure switch/gage, range 0-1.5 kPa.

A3000-100CM

Pressure switch/gage, range 0-100 cm w.c.

A3000-100MM

Pressure switch/gage, range 0-100 mm w.c.

A3000-10KPA

Pressure switch/gage, range 0-10 kPa.

A3000-10MM

Pressure switch/gage, range 0-10 mm w.c.

A3000-125PA

Pressure switch/gage, range 0-125 Pa.

A3000-150CM

Pressure switch/gage, range 0-150 cm w.c.

A3000-15CM

Pressure switch/gage, range 0-15 cm w.c.

A3000-15KPA

Pressure switch/gage, range 0-15 kPa.

A3000-1KPA

Pressure switch/gage, range 0-1 kPa.

A3000-200CM

Pressure switch/gage, range 0-200 cm w.c.

A3000-20CM

Pressure switch/gage, range 0-20 cm w.c.

A3000-20KPA

Pressure switch/gage, range 0-20 kPa.

A3000-250CM

Pressure switch/gage, range 0-250 cm w.c.

A3000-250PA

Pressure switch/gage, range 0-250 Pa.

A3000-25CM

Pressure switch/gage, range 0-25 cm w.c.

A3000-25KPA

Pressure switch/gage, range 0-25 kPa.

A3000-25MM

Pressure switch/gage, range 0-25 mm w.c.

A3000-300CM

Pressure switch/gage, range 0-300 cm w.c.

A3000-30KPA

Pressure switch/gage, range 0-30 kPa.

A3000-3KPA

Pressure switch/gage, range 0-3 kPa.

A3000-4KPA

Pressure switch/gage, range 0-4 kPa.

A3000-500PA

Pressure switch/gage, range 0-500 Pa.

A3000-50CM

Pressure switch/gage, range 0-50 cm w.c.

A3000-50MM

Pressure switch/gage, range 0-50 mm w.c.

A3000-5KPA

Pressure switch/gage, range 0-5 kPa.

A3000-60PA

Pressure switch/gage, range 0-60 Pa.

A3000-6MM

Pressure switch/gage, range 0-6 mm w.c.

A3000-750PA

Pressure switch/gage, range 0-750 Pa.

A3000-80CM

Pressure switch/gage, range 0-80 cm w.c.

A3000-80MM

Pressure switch/gage, range 0-80 mm w.c.

A3000-8KPA

Pressure switch/gage, range 0-8 kPa.

A3001

Pressure switch/gage, range 0-1.0" w.c.

A3001AV

Pressure switch/gage, range 0-1.0" w.c.500-4000 FPM. Note: Pitot tube required.

A3002

Pressure switch/gage, range 0-2.0" w.c.

A3002AV

Pressure switch/gage, range 0-2.0" w.c./1000-5600 FPM. Note: Pitot tube required.

A3003

Pressure switch/gage, range 0-3.0" w.c.

A3004

Pressure switch/gage, range 0-4.0" w.c.

A3005

Pressure switch/gage, range 0-5.0" w.c.

A3006

Pressure switch/gage, range 0-6.0" w.c.

A3008

Pressure switch/gage, range 0-8.0" w.c.

A3010

Pressure switch/gage, range 0-10" w.c.

A3010AV

Pressure switch/gage, range 0-10" w.c./2000-12500 FPM. Note: Pitot tube required.

A3015

Pressure switch/gage, range 0-15" w.c.

A3020

Pressure switch/gage, range 0-20" w.c.

A3025

Pressure switch/gage, range 0-25" w.c.

A3030

Pressure switch/gage, range 0-30" w.c.

A3040

Pressure switch/gage, range 0-40" w.c.

A3050

Pressure switch/gage, range 0-50" w.c.

A3060

Pressure switch/gage, range 0-60" w.c.

A3080

Pressure switch/gage, range 0-80" w.c.

A3100

Pressure switch/gage, range 0-100" w.c.

A3150

Pressure switch/gage, range 0-150" w.c.

A3201

Pressure switch/gage, range 0-1 psi.

A3202

Pressure switch/gage, range 0-2 psi.

A3203

Pressure switch/gage, range 0-3 psi.

A3204

Pressure switch/gage, range 0-4 psi.

A3205

Pressure switch/gage, range 0-5 psi.

A3210

Pressure switch/gage, range 0-10 psi, medium pressure option standard.

A3215

Pressure switch/gage, range 0-15 psi, medium pressure option standard.

A3220

Pressure switch/gage, range 0-20 psi, medium pressure option standard.

A3230

Pressure switch/gage, range 0-30 psi, high pressure option standard.

A3300-0

Pressure switch/gage, range .25-0-.25" w.c.

A3300-1KPA

Pressure switch/gage, range .5-0-.5 kPa.

A3300-20MM

Pressure switch/gage, range 10-0-10 mm w.c.

A3300-250PA

Pressure switch/gage, range 125-0-125 Pa.

A3300-30MM

Pressure switch/gage, range 15-0-15 mm w.c.

A3300-3KPA

Pressure switch/gage, range 1.5-0-1.5 kPa.

A3300-500PA

Pressure switch/gage, range 250-0-250 Pa.

A3301

Pressure switch/gage, range .5-0-.5" w.c.

A3302

Pressure switch/gage, range 1-0-1" w.c.

A3304

Pressure switch/gage, range 2-0-2" w.c.

A3310

Pressure switch/gage, range 5-0-5" w.c.

A3320

Pressure switch/gage, range 10-0-10" w.c.

A3330

Pressure switch/gage, range 15-0-15" w.c.

Specifications

GAGE SPECIFICATIONS

Service:Air and non-combustible, compatible gases.

Wetted Materials:Consult Factory.

Accuracy:±2% of FS at 70°F (21.1°C). ±3% on -0 and ±4% on -00 models.

Pressure Limits:-20" Hg. to 25 psig (-0.677 to 1.72 bar). MP option; 35 psig (2.41 bar), HP option; 80 psig (5.52 bar).

Temperature Limits:20 to 120°F. (-6.67 to 48.9°C). -20 to 120°F (-28 to 48.9°C) with low temperature option.

Process Connections:1/8" female NPT.

Size:4" (101.6 mm) dial face, 5" (127 mm) O.D. x 8-1/4" (209.55 mm).

Weight:4 lb (1.81 kg).

SWITCH SPECIFICATIONS

Switch Type:Each setpoint has 2 Form C relays (DPDT).

Repeatability:±1% of FS.

Electrical Rating:10 A @ 28 VDC, 10 A @ 120, 240 VAC.

Electrical Connections:Screw terminals. Use 167°F (75°C) copper conductors only.

Power Requirements:120 VAC, 50/60 Hz; 240 VAC & 24 VAC power optional.

Mounting Orientation:Diaphragm in vertical position. Consult factory for other position orientations.

Set Point Adjustment:Adjustable knobs on face.

Agency Approvals:CE, CSA, UL.

 

Features

Bezel and front cover (with set point knobs and zero adjustment screw) removed to expose Photohelic® switch/gage set point mechanism. Cover is clear polycarbonate plastic.

Gage pointer and light shutter are mounted on helix and balancing counterweight. Shutter passes through slot in optical limit switch to expose phototransistors to integral infrared light source or mask them depending on applied pressure.

Light shield effectively protects phototransistors from strong outside light sources yet allows free pointer movement. It also gives interior a clean "finished" look.

Optical limit switches are used for reliability and long service life. Attached directly to set pointers, they are individually aligned to assure precise switching accuracy.

Semi-Flexible drive shaft connects to set point knobs.

Zero adjustment screw connects to screw in cover to adjust zero pressure reading.

Plastic enclosure protects electronic components and electrical connections.

Polycarbonate connection or terminal board is self-extinguishing.

Glass epoxy printed circuit boards for durability and permanence.

Load relays are DPDT with latching feature for maximum application versatility.

Electronics are designed to operate on 50/60 Hz, 120 volt current with 10% over or under voltage. Special units for other voltages are available.

Switch set pointers show switch settings at all times.

Spring loaded friction clutch prevents operator damage of set point mechanism.

3-in-1 instrument allows the reduction of several instruments with one product, saving inventory, installation time and money.

Patented design and 1% full scale dead band provides quick response to pressure changes means no delay in switching and chatter-free operation.

A wide range of models that can meet pressure measurement specifications from low to very high.

Options

-SR Single contact, right set point, for actuation on increasing or decreasing pressure.

-OLS OEM Model, less relay and transformer components and housing but including infared diodes and phototransistor(s), light shutter and set pointer(s). For single or double contact.

-RMR Remote-Mounted Relay, relay pack may be mounted remotely from gage. Standard length is 5 ft. For other lengths, specify cable length required.

-TAMP Tamper-proof knobs, low temperature option, special scales, voltages and other features and modifications are available.

Special Housings available include Weatherproof (NEMA 4) and Explosion-proof (NEMA 7 & 9; NEC Cl I, Gr C&D; Cl II, Gr E, F&G; Cl III). Contact Customer Service for detailed dimension drawings.

Scale No. 3401 Square Root Specify Range.

Scale No. 3402 Blank Scale Specify Range.

High & Low Latching Circuits. Dwyer Photohelic® switch/gages can be wired for high-latching, low-latching or combination high-low latching circuits. That is, the equipment will hold in these respective positions once activated and until manually reset. This can be particularly useful for alarm and signal applications where control is accomplished by another Photohelic® switch/gage or other means. Complete wiring and operational instructions are included. Where manual reset is required a dry circuit push button such as Dwyer Part A-601 should be used.

 

Accessories

Model NumberDescription

 

A-601Manual reset switch.

A-298Flat aluminum bracket for flush mounting Photohelic® & Capsuhelic® gages, 603A, 605, and 3000

 

Related Products

  • Series DH Digihelic Differential Pressure Controller
  • Series 3000MR/3000MRS Photohelic® Switch/Gage
  • Series MS Magnesense Differential Pressure Transmitter
  • Series DCT1000 Dust Collector Timer Controller
  • Series DHII Digihelic Differential Pressure Controller
  • Series DH3 Digihelic Differential Pressure Controller
  • Series ADPS/EDPS Differential Pressure Switch
  •  

Enter Buying Requirement Details
Email Id
Mobile number

Other Products in 'DWYER Series A3000 Photohelic Pressure Switch-Gage' category



Back to top