Dwyer A3300-250PA Photohelic Pressure Switch Gauge Range 125-0-125 Pa. Dwyer A3300-250PA Photohelic Pressure Switch Gauge Range 125-0-125 Pa. Dwyer A3300-250PA Photohelic Pressure Switch Gauge Range 125-0-125 Pa. Dwyer A3300-250PA Photohelic Pressure Switch Gauge Range 125-0-125 Pa. Dwyer A3300-250PA Photohelic Pressure Switch Gauge Range 125-0-125 Pa. Dwyer A3300-250PA Photohelic Pressure Switch Gauge Range 125-0-125 Pa.
Dwyer A3300-250PA Photohelic Pressure Switch Gauge Range 125-0-125 Pa.
Dwyer A3300-250PA Photohelic Pressure Switch Gauge Range 125-0-125 Pa. Dwyer A3300-250PA Photohelic Pressure Switch Gauge Range 125-0-125 Pa. Dwyer A3300-250PA Photohelic Pressure Switch Gauge Range 125-0-125 Pa. Dwyer A3300-250PA Photohelic Pressure Switch Gauge Range 125-0-125 Pa. Dwyer A3300-250PA Photohelic Pressure Switch Gauge Range 125-0-125 Pa.

Dwyer A3300-250PA Photohelic Pressure Switch Gauge Range 125-0-125 Pa.

40000 INR/Piece

Product Details:

  • Product Type Series A3000
  • Size 4" (101.6 mm) Dial Face,5 x 8" (127 x 209.55 MM)
  • Display 4" (101.6 mm) Dial Face,5 x 8" (127 x 209.55 MM)
  • Usage Air And Non Combustible,Compatible Gases
  • Processing Type Standard
  • Diameter 4" (101.6 mm) Dial Face,5 x 8" (127 x 209.55 MM) Millimeter (mm)
  • Mount Type Surface
  • Click to View more
X

Dwyer A3300-250PA Photohelic Pressure Switch Gauge Range 125-0-125 Pa. Price And Quantity

  • 40000 INR/Piece
  • 1 Piece

Dwyer A3300-250PA Photohelic Pressure Switch Gauge Range 125-0-125 Pa. Product Specifications

  • Surface
  • Standard
  • Air And Non Combustible,Compatible Gases
  • Series A3000
  • Gas
  • 4" (101.6 mm) Dial Face,5 x 8" (127 x 209.55 MM)
  • 4" (101.6 mm) Dial Face,5 x 8" (127 x 209.55 MM)
  • 4" (101.6 mm) Dial Face,5 x 8" (127 x 209.55 MM) Millimeter (mm)
  • A3300-250PA Range 125-0-125 Pa.

Dwyer A3300-250PA Photohelic Pressure Switch Gauge Range 125-0-125 Pa. Trade Information

  • Cash Against Delivery (CAD) Cash on Delivery (COD) Letter of Credit at Sight (Sight L/C) Telegraphic Transfer (T/T) Paypal Letter of Credit (L/C) Western Union Delivery Point (DP) Days after Acceptance (DA) Cash in Advance (CID) Cheque Cash Advance (CA)
  • Sample costs shipping and taxes has to be paid by the buyer
  • www.envirotechdelhi.net
  • Asia Australia North America South America Eastern Europe Western Europe Middle East Central America Africa
  • Tripura Manipur Chandigarh Himachal Pradesh Meghalaya Andaman and Nicobar Islands Pondicherry Daman and Diu Dadra and Nagar Haveli Lakshadweep South India East India West India Andhra Pradesh Assam Arunachal Pradesh Bihar Delhi Gujarat Goa Haryana Jammu and Kashmir Jharkhand Karnataka Madhya Pradesh Maharashtra Mizoram Punjab Rajasthan Sikkim Telangana Nagaland Uttarakhand West Bengal Tamil Nadu North India Kerala Central India Odisha Uttar Pradesh Chhattisgarh All India
  • YAS

Product Description

Dwyer A3300-250PA Photohelic Pressure Switch Gauge Range 125-0-125 Pa.

Dwyer A3300-250PA Photohelic Pressure Switch/Gauge (125-0-125 Pa.)

Model: A3300-250PA

Bezel and front cover (with set point knobs and zero adjustment screw) removed to expose Photohelic® Switch/Gage set point 

Mechanism. Cover is Clear Polycarbonate Plastic. Gage Pointer and Light Shutter Are Mounted on Helix and Balancing 

Counterweight.

Dwyer A3300-250PA Offers

Features

  • Measure 4 to 20 mA Signals Without "Breaking the Loop"
  • Measure mA Signals For PLC and Control System Analog I/O
  • Dual Backlit Display With Both mA Measurement And Percent of 4 to 20 mA Span
  • Measurement Spotlight illuminates hard to see wires in dark enclosures
  • Detachable clamp with extension cable for measurements in tight locations
  • Measure 10 to 50 mA signals in older control systems using the 99.9 mA range
  • Automatically change the 4 to 20 mA output for remote testing
  • Power saving features, auto-off, backlight timeout extend battery life
  • Hold function captures and displays changing measurements

Applications

  • Air Conditioner Systems
  • Clean Rooms
  • Fume Exhaust Systems

Dwyer A3300-250PA Specifications

Switch Specifications

  • Switch Type:Each Set Point Has 2 Form C Relays (DPDT)
  • Repeatability:±1% of FS
  • Electrical Rating:10 A at 28 VDC,10 A at 120,240 VAC
  • Electrical Connections:Screw Terminals. Use 167°F (75°C) Copper Conductors Only
  • Power Requirements:120 VAC, 50/60 Hz,240 VAC and 24 VAC power optional
  • Mounting Orientation:Diaphragm in Vertical Position. Consult Factory For Other Position Orientations
  • Set Point Adjustment:Adjustable Knobs On Face
  • Agency Approvals:CE, CSA, UL

 

Gauge Specifications

  • Service:Air And Non Combustible,Compatible Gases
  • Accuracy:±2% of FS at 70°F (21.1°C),±3% on -0,±4% on -00 models
  • Pressure Limits:-20" Hg to 25 psig (-0.677 to 1.72 bar),MP option; 35 psig (2.41 bar),HP option; 80 psig (5.52 bar)
  • Temperature Limits:20 to 120°F. (-6.67 to 48.9°C),-20 to 120°F (-28 to 48.9°C) with low temperature option
  • Process Connections:? female NPT
  • Dimensions:4" (101.6 mm) Dial Face,5 x 8¼" (127 x 209.55 MM)
  • Weight:4 lb (1.81 kg)