Dwyer A3008 Photohelic Pressure Switch Gauge Range 0-8.0 Inch w.c. Dwyer A3008 Photohelic Pressure Switch Gauge Range 0-8.0 Inch w.c. Dwyer A3008 Photohelic Pressure Switch Gauge Range 0-8.0 Inch w.c. Dwyer A3008 Photohelic Pressure Switch Gauge Range 0-8.0 Inch w.c. Dwyer A3008 Photohelic Pressure Switch Gauge Range 0-8.0 Inch w.c. Dwyer A3008 Photohelic Pressure Switch Gauge Range 0-8.0 Inch w.c.
Dwyer A3008 Photohelic Pressure Switch Gauge Range 0-8.0 Inch w.c.
Dwyer A3008 Photohelic Pressure Switch Gauge Range 0-8.0 Inch w.c. Dwyer A3008 Photohelic Pressure Switch Gauge Range 0-8.0 Inch w.c. Dwyer A3008 Photohelic Pressure Switch Gauge Range 0-8.0 Inch w.c. Dwyer A3008 Photohelic Pressure Switch Gauge Range 0-8.0 Inch w.c. Dwyer A3008 Photohelic Pressure Switch Gauge Range 0-8.0 Inch w.c.

Dwyer A3008 Photohelic Pressure Switch Gauge Range 0-8.0 Inch w.c.

40000 INR/Piece

Product Details:

  • Weight 4 lb (1.81 kg) Kilograms (kg)
  • Usage Air and non-combustible, compatible gases
  • Size 4" (101.6 mm) dial face,5 x 8" (127 x 209.55 mm)
  • Display 4" (101.6 mm) dial face,5 x 8" (127 x 209.55 mm)
  • Product Type Series A3000
  • Processing Type Standard
  • Diameter 4" (101.6 mm) dial face,5 x 8" (127 x 209.55 mm) Millimeter (mm)
  • Click to View more
X

Dwyer A3008 Photohelic Pressure Switch Gauge Range 0-8.0 Inch w.c. Price And Quantity

  • 1 Piece
  • 40000 INR/Piece

Dwyer A3008 Photohelic Pressure Switch Gauge Range 0-8.0 Inch w.c. Product Specifications

  • Air and non-combustible, compatible gases
  • 4 lb (1.81 kg) Kilograms (kg)
  • Gas
  • A3008 Range 0-8.0" w.c
  • 4" (101.6 mm) dial face,5 x 8" (127 x 209.55 mm)
  • 4" (101.6 mm) dial face,5 x 8" (127 x 209.55 mm)
  • Standard
  • 4" (101.6 mm) dial face,5 x 8" (127 x 209.55 mm) Millimeter (mm)
  • Series A3000

Dwyer A3008 Photohelic Pressure Switch Gauge Range 0-8.0 Inch w.c. Trade Information

  • Cash Against Delivery (CAD) Cash on Delivery (COD) Paypal Letter of Credit (L/C) Western Union Letter of Credit at Sight (Sight L/C) Telegraphic Transfer (T/T) Delivery Point (DP) Days after Acceptance (DA) Cash in Advance (CID) Cheque Cash Advance (CA)
  • Sample costs shipping and taxes has to be paid by the buyer
  • EXTRA
  • Western Europe Australia South America Eastern Europe Middle East Africa Central America Asia North America
  • Himachal Pradesh Tripura Andaman and Nicobar Islands Uttarakhand Daman and Diu Dadra and Nagar Haveli Lakshadweep East India Andhra Pradesh Assam Arunachal Pradesh Chandigarh Delhi Gujarat Goa Haryana Jammu and Kashmir Jharkhand Karnataka Nagaland Madhya Pradesh Maharashtra Mizoram Meghalaya Manipur Odisha Punjab Pondicherry Rajasthan Sikkim Tamil Nadu Telangana Uttar Pradesh West Bengal South India North India Bihar Kerala Central India West India Chhattisgarh All India
  • YAS

Product Description

Dwyer A3008 Photohelic Pressure Switch Gauge Range 0-8.0 Inch w.c.

Dwyer A3008 Photohelic Pressure Switch/Gauge (0-8.0"w.c.)

Model: A3008

Bezel and front cover (with set point knobs and zero adjustment screw) removed to expose Photohelic switch/gage set point mechanism. Cover is clear polycarbonate plastic. Gage pointer and light shutter are mounted on helix and balancing counterweight.

 

Dwyer A3008 PRESSURE SWITCH GAUGE, 0-8 in WC CSA

  • Measure 4 to 20 mA signals without breaking the loop
  • Measure mA signals for PLC and control system analog I/O
  • Dual backlit display with both mA measurement and percent of 4 to 20 mA span
  • Measurement Spotlight illuminates hard to see wires in dark enclosures
  • Detachable clamp with extension cable for measurements in tight locations
  • Measure 10 to 50 mA signals in older control systems using the 99.9 mA range
  • Automatically change the 4 to 20 mA output for remote testing
  • Power saving Features, auto-off, backlight timeout extend battery life

Dwyer A3008 Specifications

Switch Specifications

  • Switch Type:Each set point has 2 Form C relays (DPDT)
  • Repeatability:1% of FS
  • Electrical Rating:10 A at 28 VDC,10 A at 120,240 VAC
  • Electrical Connections:Screw terminals. Use 167F (75C) copper conductors only
  • Power Requirements:120 VAC, 50/60 Hz,240 VAC and 24 VAC power optional
  • Mounting Orientation:Diaphragm in vertical position. Consult factory for other position orientations
  • Set Point Adjustment:Adjustable knobs on face
  • Agency Approvals:CE, CSA, UL

Gauge Specifications

  • Service:Air and non-combustible, compatible gases
  • Accuracy:2% of FS at 70F (21.1C),3% on -0,4% on -00 models
  • Pressure Limits:-20" Hg to 25 psig (-0.677 to 1.72 bar),MP option; 35 psig (2.41 bar),HP option; 80 psig (5.52 bar)
  • Temperature Limits:20 to 120F. (-6.67 to 48.9C),-20 to 120F (-28 to 48.9C) with low temperature option
  • Process Connections: female NPT
  • Dimensions:4" (101.6 mm) dial face,5 x 8" (127 x 209.55 mm)
  • Weight:4 lb (1.81 kg)