Aerosense Clean Room Monitor

Aerosense Clean Room Monitor

Product Details:

X

Product Description

Aerosense Clean Room Monitor

Series ADPRHT Clean Room Monitor

APPLICATION

Multi-Parameter Display/Transmitter measures Differential Pressure, Humidity, Temperature and optional clock. Series ADPRHT, Multi-parameter display/transmitter measures Differential Pressure, Humidity, Temperature and optional clock. Panel mount/rectangular type cut out for modular wall mounting with stainless steel front plate. Built-in high and low buzzer alarm for process set parameter.

Product Applications:

  • Pharma Cleanrooms, HVAC, Environmental, Pharma machinery, across filters, Hospital isolation room, operation theatres and laboratories.
  • Precision of measurement in HVAC duct pressure application makes this instrument suitable for optimization of energy.
  • Analog output & RS485 communication lead to easy integration with variable frequency drives and SCADA/BMS systems.

Sensor Type:

  • Polymer sensing for Temperature
  • Capacitive polymer sensing for Relative Humidity
  • Piezo Resistive Sensor for Differential Pressure

Range:

  • -30.0 to +50.0 Deg. C typical for Temperature
  • 0.0 to 100.0 % RH typical for Relative humidity
  • 0.0 to +25.0 mm. W.C. / 0 to 250 Pascals (Any other customized range as per user specifications)

Resolution:

  • Fixed 0.1 for both Temperature and Relative humidity 0.1 mm. W.C. or 1 Pascal for Differential Pressure

Accuracy:

  • 0.5 C for -30 to 50 C for Temperature
  • +/- 1.8% for 10 to 95% RH for Relative humidity
  • +/- 0.5% F.S. for Differential Pressure

Display:

  • 3 Line Red 7 Segment LED Display.
  • 4 Digits for Differential Pressure on Line 1.
  • 4 Digits for % RH. (Humidity) on Line 2.
  • 4 Digits on Temperature (Deg. C) on Line 3.

TECHNCAL SPECIFICATIONS

Display Height Options:
 -0.4 High Standard, Optional 1 High Display

Differential Pressure Entry: 2 Nos. 4 mm. Hose Nipples at top.

Setting: By 4 keys on the front stainless steel panel.

Buzzer: Integrated buzzer for Alarm in case of process violation of any of the 3 parameters

Supply Voltage: 24VDC , 250mA

Mounting: Wall mounting / Modular Wall Mounting with Stainless Steel Front Flush Plate for Clean Rooms

Sensors: Integrated Humidity & Temperature Sensor flushed to front plate Built in differential pressure sensor with Brass HoseNipples (Chrome Plated) for Differential Pressure At Rear ( 4 mm x 2 Nos.) Optional External Humidity & Temperature Sensor

Communication: RS 485 Modbus Protocol (Optional)

Output: 4-20mA (Optional)

Dimension: Enclosure: 74(W) x 72(H) x 40(D) mm.

Stainless Steel Front Plate: 110W x 90(H) mm

Enclosure: M.S. Power Coated body with Stainless Steel Front Flush Plate for Modular Wall Mounting/Optional Brick Wall Mounting.

Weight: 300 gms. Approx.

Enter Buying Requirement Details